Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Features

Unit Function Section

The combined air conditioning unit of the clean operating room can be designed with different air treatment functional sections: fresh return air mixing section, primary filter section, surface cold dehumidification section, heating section, humidification section, secondary return air mixing section, fan section, and current equalization section , Medium-efficiency filter section, sub-high-efficiency filter section, sterilization section, air supply section, host side, etc., through the unit function section to perform one or more treatments on the air to meet the required technical requirements for working conditions and effects

Function section name

1

Mixed section

7

Current sharing section

2

Primary-efficiency filter section

8

Medium-efficiency filter section

3

Coil dehumidification section

9

Sub-high efficiency filter section

4

Heater section

10

Sterilization section

5

Humidification section

11

Wind out section

6

Fan section

12

Host segment


Features
1. High-strength structure: adopts high-strength cooling bridge aluminum alloy profile frame, beautiful appearance and high strength;
2. No deformation: The inner and outer panels and the insulation layer are foamed at one time, and the foaming density is not less than 48kg/m3, which can ensure that the unit does not deform under the pressure difference between the inside and outside of 2500Pa;
3. Anti-cold bridge: high-strength anti-cold bridge aluminum alloy structure, PA66 heat insulation material, completely solve the frame condensation problem;
4. Low air leakage rate: regardless of positive pressure or negative pressure, the air leakage rate is less than 1% under the pressure difference of 1000 Pa between the inside and outside of the machine;
5. Personalized design: improve non-standard customized designs such as annual refrigeration, low-temperature heating, low-temperature air supply, and compressor frequency conversion, and tailor-made technical solutions for clean projects.

Application

• Clean rooms and controlled environments

• Healthcare, pharmaceuticals, electronics, and precision machinery

• Laboratories, research centers, and hospitals

• Light and chemical industries

• Large public buildings with precise air purification and temperature/humidity control

Technical Data

Unit quick selection table(air volume):

Model

Nominal air volume m³/h

Windward area of coil㎡

Wind speed of the coil(m/s)

2.00

2.25

2.50

2.75

3.00

3.25

m³/h

0606

1500

0.16

1152

1296

1440

1584

1728

1872

0706

1800

0.2

1440

1620

1800

1980

2160

2340

0806

2200

0.24

1728

1944

2160

2376

2592

2808

0907

3200

0.35

2520

2835

3150

3465

3780

4095

0908

3800

0.42

3024

3402

3780

4158

4536

4914

1009

5000

0.56

4032

4536

5040

5544

6048

6552

1209

6300

0.7

5040

5670

6300

6930

7560

8190

1210

7200

0.8

5760

6480

7200

7920

8640

9360

1510

9500

1.04

7488

8424

9360

10296

11232

12168

1512

12000

1.3

9360

10530

11700

12870

14040

15210

1515

15000

1.69

12168

13689

15210

16731

18252

19773

1815

18000

2.08

14976

16848

18720

20592

22464

24336

1818

23000

2.56

18432

20736

23040

25344

27648

29952

2118

27000

3.04

21888

24624

27360

30096

32832

35568

2121

32000

3.61

25992

29241

32490

35739

38988

42237

2421

37000

4.18

30096

33858

37620

41382

45144

48906

2721

43000

4.75

34200

38475

42750

47025

51300

55575

2724

50000

5.5

39600

44550

49500

54450

59400

64350

3024

55000

6.16

44352

49896

55440

60984

66528

72072

3027

63000

7

50400

56700

63000

69300

75600

81900

3030

70000

7.84

56448

63504

70560

77616

84672

91728

3627

76000

8.5

61200

68850

76500

84150

91800

99450

3630

85000

9.52

68544

77112

85680

94248

102816

111384

3930

93000

10.36

74592

83916

93240

102564

111888

121212

3933

100000

11.47

82584

92907

103230

113553

123876

134199

3936

110000

12.58

90576

101898

113220

124542

135864

147186


Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.

Unit quick selection table(cooling capacity of coil section under return air condition):

Model

Nominal air volume m³/h

4 rows

6 rows

8 rows

Cooling capacity

Water volume

Cooling capacity

Water volume

Cooling capacity

Water volume

kW

m³/h

kW

m³/h

kW

m³/h

0606

1500

8.2

1.4

10.9

1.87

13.2

2.27

0706

1800

10.2

1.8

13.6

2.34

16.5

2.84

0806

2200

12.6

2.2

16.4

2.82

19.8

3.41

0907

3200

17.8

3.1

23.8

4.09

28.8

4.95

0908

3800

21.5

3.7

28.6

4.92

34.6

5.95

1009

5000

28.7

4.9

38.1

6.55

46.2

7.95

1209

6300

35.8

6.2

47.8

8.22

57.5

9.89

1210

7200

41.1

7.1

54.6

9.39

66.1

11.37

1510

9500

53.3

9.2

70.8

12.18

85.6

14.72

1512

12000

66.7

11.5

88.6

15.24

107.1

18.42

1515

15000

86.6

14.9

115.3

19.83

138.6

23.84

1815

18000

106.5

18.3

141.8

24.39

170.3

29.29

1818

23000

131.2

22.6

172.9

29.74

210.5

36.21

2118

27000

155.8

26.8

206.8

35.57

248.6

42.76

2121

32000

185.1

31.8

245.2

42.17

296.5

51.00

2421

37000

214.2

36.8

285.1

49.04

341.8

58.79

2721

43000

243.3

41.8

323.6

55.66

385.6

66.32

2724

50000

281.5

48.4

374.5

64.41

450.3

77.45

3024

55000

315.7

54.3

419.3

72.12

500.4

86.07

3027

63000

358.6

61.7

476.5

81.96

560.4

96.39

3030

70000

400.5

68.9

534.1

91.87

640.5

110.17

3627

76000

432.6

74.4

578.2

99.45

690.5

118.77

3630

85000

482.5

83.0

645.8

111.08

765.8

131.72

3930

93000

520.6

89.5

702.3

120.80

830.5

142.85

3933

100000

576.1

99.1

778.4

133.88

940.8

161.82

3936

110000

630.6

108.5

850.6

146.30

970.5

166.93

Note:
1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;
2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(cooling capacity of coil section under fresh air condition):

Model

Nominal air volume m³/h

4 rows

6 rows

8 rows

Cooling capacity

Water volume

Cooling capacity

Water volume

Cooling capacity

Water volume

kW

m³/h

kW

m³/h

kW

m³/h

0606

1500

18.9

3.3

23.5

4.04

28.1

4.83

0706

1800

23.5

4.0

29.4

5.06

35.1

6.04

0806

2200

28.3

4.9

35.3

6.07

42.2

7.25

0907

3200

41.3

7.1

51.4

8.84

61.5

10.57

0908

3800

49.5

8.5

61.7

10.61

73.8

12.69

1009

5000

66.2

11.4

82.3

14.15

98.4

16.92

1209

6300

82.3

14.2

102.8

17.68

122.9

21.15

1210

7200

94.5

16.3

117.5

20.21

140.5

24.17

1510

9500

122.9

21.1

152.8

26.27

182.7

31.42

1512

12000

153.2

26.4

190.9

32.84

228.3

39.27

1515

15000

195.6

33.6

248.2

42.69

296.8

51.05

1815

18000

245.6

42.2

305.5

52.55

365.3

62.83

1818

23000

302.1

52.0

376.0

64.67

449.6

77.33

2118

27000

358.7

61.7

446.5

76.80

533.9

91.83

2121

32000

426.1

73.3

530.2

91.20

634.0

109.05

2421

37000

492.8

84.8

613.9

105.60

734.1

126.27

2721

43000

560.8

96.5

697.7

120.00

834.2

143.49

2724

50000

648.9

111.6

807.8

138.94

965.9

166.14

3024

55000

727.6

125.1

904.8

155.62

1081.9

186.08

3027

63000

826.4

142.1

1028.1

176.84

1229.4

211.45

3030

70000

924.8

159.1

1151.5

198.06

1376.9

236.83

3627

76000

1005.4

172.9

1248.4

214.73

1492.8

256.76

3630

85000

1124.3

193.4

1398.3

240.50

1672.0

287.58

3930

93000

1200.6

206.5

1514.6

260.51

1812.4

311.73

3933

100000

1320.6

227.1

1671.4

287.48

2010.3

345.77

3936

110000

1450.7

249.5

1825.7

314.02

2186.5

376.08

Note:
1. The inlet temperature of chilled water is 7℃, and the outlet temperature is 12℃;
2. Fresh air conditions: inlet air dry bulb temperature 35℃, wet bulb temperature 28℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.

Unit quick selection table(hot water coil heating capacity):

Model

Nominal air volume m³/h

Return air condition

Fresh air condition

2 rows

3 rows

4 rows

2 rows

3 rows

4 rows

heating capacity

heating capacity

heating capacity

heating capacity

heating capacity

heating capacity

kW

kW

kW

kW

kW

kW

0606

1500

9.4

12.5

14.8

11.1

15.1

18.1

0706

1800

11.8

15.6

18.5

13.9

18.9

22.6

0806

2200

14.1

18.8

22.2

16.7

22.7

27.2

0907

3200

20.6

27.3

32.4

24.3

33.0

39.6

0908

3800

24.7

32.8

38.9

29.1

39.6

47.5

1009

5000

32.9

43.8

51.8

38.9

52.9

63.4

1209

6300

41.1

54.7

64.8

48.6

66.1

79.2

1210

7200

47.0

62.5

74.0

55.5

75.5

90.5

1510

9500

61.1

81.3

96.2

72.2

98.2

117.7

1512

12000

76.4

101.6

120.3

90.2

122.7

147.1

1515

15000

99.3

132.0

156.3

117.2

159.5

191.2

1815

18000

122.2

162.5

192.4

144.3

196.3

235.3

1818

23000

150.4

200.0

236.8

177.6

241.6

289.6

2118

27000

178.6

237.5

281.2

210.9

286.9

343.9

2121

32000

212.1

282.0

333.9

250.4

340.7

408.4

2421

37000

245.6

326.6

386.7

290.0

394.5

472.9

2721

43000

279.1

371.1

439.4

329.5

448.3

537.3

2724

50000

323.1

429.7

508.8

381.6

519.1

622.2

3024

55000

361.9

481.3

569.8

427.4

581.4

696.9

3027

63000

411.3

546.9

647.5

485.6

660.6

791.9

3030

70000

460.6

612.5

725.2

543.9

739.9

886.9

3627

76000

499.4

664.1

786.3

589.7

802.2

961.6

3630

85000

559.3

743.8

880.6

660.5

898.5

1077.0

3930

93000

608.7

809.4

958.3

718.7

977.7

1172.0

3933

100000

673.9

896.1

1061.0

795.7

1082.5

1297.5

3936

110000

739.1

982.8

1163.7

872.7

1187.2

1423.1

Note:
1. The inlet temperature of hot water is 60°C, and the outlet temperature is 50°C;
2. Return air condition: inlet air dry bulb temperature 15℃; fresh air condition: inlet air dry bulb temperature 7℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Unit quick selection table(hot water coil heating capacity):

Model

Nominal air volume m³/h

One row of steam heating

Two rows of steam heating

Steam pressure

Steam pressure

0.1MPa

0.2MPa

0.3MPa

0.1MPa

0.2MPa

0.3MPa

kW

kW

kW

kW

kW

kW

0606

1500

8.9

10.2

11.1

14.3

16.2

17.6

0706

1800

11.1

12.8

13.9

17.9

20.3

22.0

0806

2200

13.4

15.3

16.7

21.5

24.3

26.4

0907

3200

19.5

22.3

24.3

31.3

35.4

38.5

0908

3800

23.4

26.8

29.1

37.5

42.5

46.2

1009

5000

31.2

35.7

38.9

50.1

56.7

61.6

1209

6300

38.9

44.6

48.6

62.6

70.9

77.0

1210

7200

44.5

51.0

55.5

71.5

81.0

88.0

1510

9500

57.9

66.3

72.2

93.0

105.3

114.4

1512

12000

72.3

82.9

90.2

116.2

131.6

143.0

1515

15000

94.0

107.7

117.2

151.0

171.1

185.9

1815

18000

115.7

132.6

144.3

185.9

210.6

228.8

1818

23000

142.4

163.2

177.6

228.8

259.2

281.6

2118

27000

169.1

193.8

210.9

271.7

307.8

334.4

2121

32000

200.8

230.1

250.4

322.6

365.5

397.1

2421

37000

232.5

266.5

290.0

373.6

423.2

459.8

2721

43000

264.2

302.8

329.5

424.5

480.9

522.5

2724

50000

305.9

350.6

381.6

491.6

556.9

605.0

3024

55000

342.7

392.7

427.4

550.6

623.7

677.6

3027

63000

389.4

446.3

485.6

625.6

708.8

770.0

3030

70000

436.1

499.8

543.9

700.7

793.8

862.4

3627

76000

472.8

541.9

589.7

759.7

860.6

935.0

3630

85000

529.6

606.9

660.5

850.9

963.9

1047.2

3930

93000

576.3

660.5

718.7

925.9

1049.0

1139.6

3933

100000

638.0

731.2

795.7

1025.1

1161.3

1261.7

3936

110000

699.8

802.0

872.7

1124.3

1273.7

1383.8


Note:
1. Heating conditions, the inlet air dry bulb temperature is 7℃;
2. The structure of the heater is a steel pipe wound around a steel fin;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Part List
Mixed section
The air mixing section is used to mix air in different states, and to control and adjust the flow of air. Generally, it is equipped with a return air inlet and a fresh air outlet, and is equipped with a manual or electric air volume control valve.

Primary-efficiency filter section
The primary filter section is used at the front end of the entire unit to intercept large particles such as dust and hair in the air, which can prolong the service life of the secondary filter. According to different wind speed, material, grade, thickness and technology, the initial resistance of the initial filter section is 150Pa, and the final resistance is about 120Pa.

Medium-efficiency filter section
The medium-efficiency filter section is used at the back end of the primary filter section to intercept large particles such as dust and hair in the air, which can prolong the use of the post-filter. According to different wind speed, material, grade, thickness and process, the initial resistance of the initial filter section is 15-50Pa, and the final resistance is 120Pa.

Sub-high-efficiency/high-efficiency filter section
The sub-high-efficiency filter section is used at the back end of the medium-efficiency filter section, intercepting dust and impurities with a particle size of 0.5μm in the air, with a moderate collection efficiency, which can extend the service life of the subsequent filter.
According to the wind speed, material, grade, thickness and process of the medium-efficiency filter section, its return force is 30-60Pa, and the final resistance is about 150Pa.
The filtration efficiency of the high-efficiency filter section can reach 99%, and its final resistance is about 300Pa. It is mostly used in high-grade clean rooms, operating rooms and other places with high cleanliness requirements.

Surface cold dehumidification section
The surface cold dehumidification section is used to cool and dehumidify the air, and play a role in regulating the environment and environmental humidity. Generally divided into chilled water type and refrigerant direct expansion type.

Heating section
It is generally placed after the surface cooling section to adjust the ambient temperature. It is generally divided into three types: hot water type, steam type and electric heating type.

Humidification section
It is generally placed after the heating section to adjust the temperature of the environment, and is generally divided into dry steam type, electrode type, high pressure micro mist type, ultrasonic wave and wet curtain.

Fan section
It is used to make the air in the local environment pass through the combined air conditioning unit and circulate, and do corresponding treatment according to requirements.

Sterilization section
It uses air or oxygen as raw materials to generate ozone by high-frequency and high-voltage discharge. It is recognized as a broad-spectrum and highly effective bactericide in the world. Ozone has one more active oxygen atom than oxygen molecule. It has a very active chemical property and is a strong oxidant. It can quickly kill bacteria in the air at a certain concentration, without any toxic residue, and will not form secondary pollution.